Electrical Specifications
Accuracy
± (% reading + number of digits) at 23 °C ± 5 °C at < 80 % R.H.
Temperature Coefficient
Add 0.2 x (Specified Accuracy) / °C, < 18 °C, > 28 °C
Voltage
Function Range Accuracy
V 1.3 V to 750.0 V
±(1.5% + 3 dgts)
50 Hz – 500 Hz
V
2.1 V to 1000 V ±(1% + 2 dgts)
-0.7 V to 1000 V ±(1% + 4 dgts)
Overload Protection: 1000 VDC / 750 VAC
Max Operation Time: DT = 30s for 30 V
Input Impedance: 4 k for input voltage up to 30 V.
Impedance increases with input voltage to approximately 375
k at 750 VAC.
Resistance and Continuity & Diode
Function Range Accuracy
0 to 9999 ±(2% + 2 dgts)
0.4 V to 0.8 V ±(1% + 3 dgts)
Maximum Open Circuit Voltage: 2.0 V
Overload Protection: 1000 VDC / 750 VAC
Continuity Check
Internal sound activates if the resistance of the circuit under
test is less than 25 . It will then turn off if the resistance is
increased beyond 400 . Specified from 0 °C to 40 °C.