Amprobe ACD-14-FX Clamp-On-Multimeter Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Instrumentos de medida Amprobe ACD-14-FX Clamp-On-Multimeter. Amprobe ACD-14-FX Clamp-On-Multimeter User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 19
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
User Manual
• Bedienungshandbuch
• Mode d’emploi
• Manuale d’Uso
• Manual de uso
• Bruksanvisning
ACD-14 FX
ACD-14 TRMS FX
Vista de página 0
1 2 3 4 5 6 ... 18 19

Resumo do Conteúdo

Página 1 - ACD-14 TRMS FX

User Manual• Bedienungshandbuch• Mode d’emploi• Manuale d’Uso• Manual de uso• BruksanvisningACD-14 FXACD-14 TRMS FX

Página 2

8 Diode test function Inputs are made through the test lead terminals. Move the slide-switch to the “Ω” position. The unit defaults at Ω. Press SELEC

Página 3 - Owner’s Manual

9ACA Current clamp-on functionInputs are made through the clamp on jaws for non-invasive ACA current measurements.Press the OFF push button momentaril

Página 4

10Make sure the jaws are completely closed, or else it will introduce measurement errors.Strong Electro-magnetic field environments such as high-curren

Página 5 - Safety Regulations

11Application notes:The DC µA function is designed especially for HVAC/R flame sensor applications. The 0.1µA resolution is useful for identifying the

Página 6

12Auto-rangingWhen there is more than one measuring range under a selected meter function, the LED annunciator “a” turns on in the upper left corner.

Página 7 - Product Description

13Battery replacementThe meter uses 2 standard 3V alkaline button batteries (ANSI/NEDA-5004LC, IEC-CR2030). The lower battery is used for the slide-sw

Página 8 - Operation

14SpecificationsGeneral SpecificationsDisplay: 3-3/4 digits 4000 counts, dual LCD displaysUpdate Rate: 3 per second nominalPolarity: AutomaticLow Batter

Página 9

15Standard Accessories:Test leads (pair), banana plug style, bead Type-K Thermocouple, batteries, user’s manual, & soft carrying case.Replacement

Página 10

16OhmsRANGE Accuracy400.0Ω 0.8% + 6d4.000kΩ, 40.00kΩ, 400.0kΩ0.6% + 4d4.000MΩ 1.0% + 4d40.00MΩ 2.0% + 4dOpen Circuit Voltage: 0.4VDC typicalAudible Co

Página 12

ACD-14 FX ACD-14 TRMS FXOwner’s Manual

Página 13

1Limited Warranty and Limitation of LiabilityYour Amprobe product will be free from defects in material and workmanship for 1 year from the date of pu

Página 14 - Maintenance

2ACD-14 FXACD-14 TRMS FXContents:Safety Regulations ...

Página 15

3Congratulations! Your new instrument has been crafted according to quality standards and contains quality components and workmanship. It has been ins

Página 16 - Specifications

4 WARNING:To reduce the risk of fire or electric shock, do not expose this product to rain or moisture. The meter is intended only for indoor use.To a

Página 17

5Product DescriptionNote: Please refer to Specification Section for function details.1) Clamp Jaw for AC current magnetic field pick up2) Hand/Finge

Página 18

6OperationDC Voltage, AC Voltage, Hz Frequency functionsInputs are made through the test lead terminals. Move the slide-switch to the “V” position. Th

Página 19

7Note: Hz input sensitivity varies automatically with function range selected while activating the Hz function. Lowest range has the highest sensitivi