Amprobe ACD-330T Clamp-On-Multimeter Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Instrumentos de medida Amprobe ACD-330T Clamp-On-Multimeter. Amprobe ACD-330T Clamp-On-Multimeter User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - Fax: 954-499-5454

Miramar, FLPhone: 954-499-5400Fax: 954-499-5454www.amprobe.com

Página 2 - USER MANUAL

ConductorMarkMARKMARKGetting Acquainted With Your MeterALIGNMENT MARKSRotary SwitchTo turn the meter on and select a function, turn the rotary switch

Página 3 - LIMITED WARRANTY

INPUT TERMINALWARNINGTo avoid damaging the meter, do not exceed input limits shown below in Table 1:The meter has two input terminals (Figure 5) that

Página 4 - TABLE OF CONTENTS

Figure 6. Push Buttons1. Press to selectDC or AC. Press and hold for more than 1 second to toggle, betweenPEAK and DC or AC.4. Press and hold for

Página 5 - SAFETY INFORMATION

Push-button OperationsThe operation of the push-buttons are outlined below. When a button is pushed, an annun-ciator lights, and the unit beeps. Turni

Página 6

5. •))) / Hzm : Continuity, Frequency• In the Ω position, press this button momentarily to toggle"-)))" continuity ON/OFF.The continuity buz

Página 7

POWER-ON OPTIONSSPECIAL FUNCTIONS INSTRUCTIONSSELECTING POWER -ON OPTIONSSome options can be selected only when you turn the meter on. These power-on

Página 8 - USING THE METER SAFELY

DYNAMIC RECORDINGThe dynamic recording mode can be used to catch intermittent and turn on or turn offsurges, verify performance, measure while you are

Página 9 - LCD DISPLAY ILLUSTRATION

Figure 7. Display of Dynamic Recording13

Página 10 - 4 •))) Ω

DATAHOLDThe data HOLD function allows operator to freeze the displayed digital value while theanalog bargraph displays present readings. Press "D

Página 11 - INPUTLIMIT

ANALOG BARGRAPHThe analog bargraph display provides a 12-segment analog reading representation. The unit of the bargraph is 100 counts/bar.Figure 10.

Página 12 - ))ON/OFF

MODEL: ACD-330TA UNIQUE CLAMP-ON MULTIMETERUSER MANUALC USLISTED

Página 13 - Push-button Operations

AUTO POWER OFFAND SLEEPMODEThere are two modes for power saving:1) The instrument will enter the "sleep" mode within 15 minutes, unless:1-1.

Página 14

(40MΩ Range (400Ω Range)DISABLE AUTO POWER OFFWhen the meter is to be used for long periods of time you may want to

Página 15 - POWER-ON OPTIONS

1 ms PEAK HOLDYou can use this Meter to analyze components such as power distribution transformersand power factor correction capacitors. The addition

Página 16

BACKLITDISPLAY FOR EASYREADING IN THE DARKPress ❊ button for more than 1 second to toggle backlight ON/OFF. Backlight turns offautomatically after 30

Página 17

Figure 16. Measuring In Rush Current.CORRECTINCORRECT20

Página 18 - Figure 8. Data Hold Operation

DISTRIBUTION TRANSFORMER MEASUREMENTYou can measure current, phase imbalance between phases, and true RMS neutral current.True RMS measurement yields

Página 19 - ANALOG BARGRAPH

Figure 17. Measuring AC Current.22

Página 20 - AUTO POWER OFFAND SLEEPMODE

ADJUSTABLE SPEED MOTOR CONTROLLERSYou can measure input current, output current and frequency of adjustable speed motorcontrollers. The output current

Página 21 - DEMONSTRATE ANNUNCIATOR

Figure 18. Measuring Input/Ouput AC Current of Controller.24

Página 22 - 1 ms PEAK HOLD

AC MOTOR CURRENTMEASUREMENTYou can measure starting (inrush) current, running current, and current imbalance in AC Motor circuits. Inrush current is t

Página 23 - AC CURRENTMEASUREMENT

LIMITED WARRANTYCongratulations! Your new instrument has been quality crafted according to quality standards and contains quality components and work

Página 24 - INCORRECT

Figure 19. Measuring AC MotorCurrent.26

Página 25

Figure 20. Measuring Voltage.AC VOLTAGE MEASUREMENT1) Set the rotary switch to “ V ”.2) Insert the black test lead to “COM” terminal and red test le

Página 26

RESISTANCE / CONTINUITYMEASUREMENTCAUTION: Make sure that power is removed and all capacitors have been dis-charged before measuring.1) Set the rotary

Página 27

DIODE CHECKA good diode allows current to flow in one direction only.To test a diode, turn thepower off, remove the diode from the circuit, and procee

Página 28

GENERALSPECIFICATIONSACDC-300 ACCESSORIES AND REPLACEMENTS PARTSAmprobe P/N DescriptionMTL-90B Safety Test Le

Página 29

DC VOLTAGEELECTRICALSPECIFICATIONSRange Resolution Accuracy Overload Protection 400V 0.1V1000V 1VAccuracy is

Página 30

CURRENT (1ms PEAK HOLD)Specified accuracy +/-40 digits for changes > 1 ms in duration.Range Resolution Accuracy 400A 0.1A ±

Página 31 - “V Ω terminal

True-RMS current is very important because it directly relates to the amount of heatdissipated in wiring, transformers, and loads. Most clamp-on meter

Página 32 - CARTRIDGE

1. The AC neutral wires must be of sufficient gauge to allow for harmonic current.2. The distribution transformer must have additional cooling to cont

Página 33 - DIODE CHECK

WAVEFORM COMPARISONTable 3. illustrates the relationship between AC and DC components for commonwaveforms, and compares readings for TRUE RMS meters a

Página 34 - GENERALSPECIFICATIONS

ACDC-3000TABLE OF CONTENTSSAFETYINFORMATION 1• INTRODUCTION 2USING THE METER SAFELY 4LCD DISPLAY ILLUSTRATION 5GETTING ACQUAINTED WITH YOUR METER 6•A

Página 35 - ELECTRICALSPECIFICATIONS

AC-COUPLEDINPUTWAVEFORMTable 3. WAVEFORM COMPARISON CHARTPEAKVOLTAGEDCCOMPONENTONLYTRUE RMS=√ ac2+dc2AC COMPONENTONLYRMS CAL OURMETERPK-PK 0-PKDC ANDA

Página 36

WARNINGTO AVOID ELECTRICAL SHOCK, DO NOT PERFORM ANY SERVICINGUNLESS YOU ARE QUALIFIED TO DO SO.SERVICEIf the instrument fails to operate, check batte

Página 37 - CURRENT HARMONICS THEORY

Figure 24. Step 2 of Battery Replacement.Pull up slightly.Figure 22. Step 1 of Battery Replacement.38

Página 38

SAFETY INFORMATIONTo ensure that youuse the meter safety, follow the safety guidelines listed below.• This meter is for indoor use, altitude up to 200

Página 39

A UNIQUE CLAMP-ON MULTIMETERINTRODUCTION Measuring current accurately is a difficult job in today's industrial plants and commercialbuildings. An

Página 40

Figure 1. A Unique Clamp-ON MultimeterOhm measurementVoltage measurementHand guard designfor more safety.Dynamic recordinghelps to record thevariation

Página 41 - MAINTENANCE

WARNINGRead “SAFETYINFORMATION” before using the meter.NOTESome typical tests are provided in this manual. These tests are designed to help you under-

Página 42 - Pull up slightly

LCD DISPLAY ILLUSTRATION1) - : Negative Polarity Annunciator2) @OFF : Auto Power Off Enabled Annunciator3) : Low Battery Annunciator4) DC : Direct Vol