Amprobe PM51A Pocket-Multimeter Manual do Utilizador Página 11

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 70
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 10
9
Special Features
Data Hold, and 30ms MAX Hold
Agency Approvals
P >
Safety: Meets IEC61010-1, UL61010B-1, CAN/CSA-C22.2 No. 1010.1-92,
CAT II 600 V and CAT III 300 V, Pollution Degree 2, Class 2
E.M.C. Meets EN61326 (1997, 1998/A1), EN61000- 4-2 (1995), and EN61000-4-3 (1996). This
product complies with requirements of the following European Community Directives: 89/ 336/ EEC
(Electromagnetic Compatibility) and 73/ 23/ EEC (Low Voltage) as amended by 93/ 68/ EEC (CE
Marking). However, electrical noise or intense electromagnetic fields in the vicinity of the equipment
may disturb the measurement circuit. Measuring instruments will also respond to unwanted signals
that may be present within the measurement circuit. Users should exercise care and take appropriate
precautions to avoid misleading results when making measurements in the presence of electronic
interference.
Accessories
Battery installed, and User’s manual
Optional Accessories:
H-PM protective holster, and VC3 soft carrying pouch
Electrical Specifications
(Accuracy @ 23
o
C ± 5
o
C and < 75% R.H.)
RF Field @ 3 V/m: Specified accuracy + 45 d (Capacitance not specified)
DC Voltage
Range Accuracy
400.0 mV ±(1.0%+2 dgt)
4.000 V, 40.00 V, 400.0 V ±(2.0%+2 dgt)
600 V ±(2.5%+4 dgt)
NMRR: > 50 dB @ 50 Hz/60 Hz
CMRR: > 120 dB @ dc, 50 Hz/60 Hz; Rs=1 k
Input Impedance: 10 M, 30 pF nominal; (1000 M for 400.0 mV range)