Amprobe IR-450 Instruções de Operação Página 1

Consulte online ou descarregue Instruções de Operação para Medição, teste e controlo Amprobe IR-450. Amprobe IR-450 Operating instructions Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 0
Users Manual
IR-450
Infrared Thermometer /
Laser Pointer / Flashlight
99 Washington Street
Melrose, MA 02176
Phone 781-665-1400
Toll Free 1-800-517-8431
Visit us at www.TestEquipmentDepot.com
Vista de página 0
1 2 3 4 5 6 ... 14 15

Resumo do Conteúdo

Página 1 - Users Manual

Users ManualIR-450Infrared Thermometer / Laser Pointer / Flashlight 99 Washington Street Melrose, MA 02176 Phone 781-665-1400Toll Free 1-800-517-8431

Página 2 - Laser Pointer / Flashlight

5Use the unit at around 30cm to get the best measurement accuracy.At longer distances, the target area shall be larger than the distance divided by 8.

Página 3

6 Allow time for the unit to adapt to the change of ambient temperatures from the user’s pocket to environmental ambient.2. The unit cannot take mea

Página 4

73. Not recommended for use in measuring shiny or polished metal surfaces (stainless steel, aluminum, etc.). See Emissivity.4. Steam, dust, smoke, etc

Página 5 - CONTENTS

8Repeatability ±1°C or ±0.5% of reading, whichever is greater.Display Hold 10 sElectrical SupplyInternally powered by 1 x AAA 1.5 Alkaline, LR03 batte

Página 6

9MAINTENANCE AND REPAIRLens Cleaning: Blow off loose particles using clean compressed air. Gently brush remaining debris away with a brush. Carefully

Página 7 - Features

10BATTERY REPLACEMENTPlease replace the battery when “Battery indicator” is flashing on display.When battery is replaced / installed, the unit will go

Página 8 - Target Area

IR-450 Infrared Thermometer / Laser Pointer / FlashlightUsers Manual4240687A©2012 Amprobe.All rights reserved. Printed in TaiwanEnglish

Página 9 - Distance and Spot Size

Limited Warranty and Limitation of LiabilityYour Amprobe product will be free from defects in material and workmanship for one year from the date of p

Página 10 - Reminders

IR-450 Infrared Thermometer / Laser Pointer / Flashlight1) Laser2) Flash light3) Display4) Flashlight button5) On button / Test button6) Battery cove

Página 11

CONTENTSSYMBOLS ... 1UNPACKING AND INSPECTION ...

Página 12 - SPECIFICATION

1SYMBOLSCaution! Refer to the explanation in this ManualLaser light: Do not stare into laser beamBatteryConform to relevant Australian standardsC

Página 13 - TROUBLESHOOTING

2CautionsThe unit should be protected from the following,• EMF (electro-magnetic elds) from arc welders and induction heaters• Static electricity•

Página 14 - MAINTENANCE AND REPAIR

3OPERATING INSTRUCTIONSPower On / OffAuto Power OffThe IR-450 will power down after not being used for 3 minutes.Auto HoldThe unit will hold the readi

Página 15 - BATTERY REPLACEMENT

4Make sure that the target is larger than the unit‘s spot size. The smaller the target, the closer you should be to it. The minimum measurement area i

Comentários a estes Manuais