TEMPERATURE (K-TYPE) MEASUREMENTS
The ACDC-620TLCD contains a dual display for
Temperature Measurement. The larger digits display
o
F (Fahrenheit), and the small
digits display
o
C (Celsius).
Both readings are displayed simultaneously.
CAUTION: Do not allow the temperature sensor to contact a surface which is ener-
gized above 30 V RMS or 60 V DC, such voltages pose a shock hazard.
To perform single input temperature measurement:
1) Set the rotary switch to "TEMP. ",
2) Insert the model TAC-DMM banana to K-type thermocouple adapter into the
meter. The "+" end of adapter must be inserted into"V - - µF" terminal.
3) Insert the model TPK-56 Type K thermocouple into the TAC-DMM.
4) Secure the beaded end of the K thermocouple to the surface you wish to
measure.
5) Press SHIFT button momentarily to enter temperature measurement mode.
6) Read the displayed temperature.